• 高級檢索

    超高性能混凝土T形截面梁受剪性能試驗研究

    Experimental study on shear behavior of UHPC-T beams

    • 摘要: 對9片超高性能混凝土(UHPC)T形梁設計進行了受剪性能試驗,分析鋼纖維摻量❓、配箍率和剪跨比等主要參數對試驗梁破壞形態、裂縫開展過程和抗剪承載力的響應影響規律🕵🏻‍♂️。基於公開發表的57片UHPC梁受剪實測數據,分析對比了既有多國規範的抗剪承載力計算方法✡︎。試驗結果表明:UHPC-T梁具有較高的抗剪承載力和延性🎾,2%~3%的配纖率有助於更好地發揮鋼纖維的抗剪貢獻,既有規範對UHPC-T梁的抗剪承載力計算偏保守,對鋼纖維的貢獻有待進一步研究。

       

      Abstract: This paper designs nine ultra-high performance concrete (UHPC) T-beams for shear performance tests and analyzes the influence of main parameters, such as steel fiber content, stirrup ratio, and shear span-to-depth ratio on the failure mode, crack propagation process, and ultimate shear strength of the test beams. Based on the published data of the ultimate shear strength of 57 UHPC beams, it compares shear strength calculation methods of existing standards from multiple countries. The results commonly indicated that a higher fiber content increased the ultimate shear strength and ductility. A fiber content ratio of 2% to 3% helps to better utilize the shear contribution of steel fibers. Shear strength equations in existing standards were found to underestimate the shear capacity of UHPC T-beams , and the contribution of steel fibers to the ultimate shear strength of UHPC requires further research.

       

    /